HIGH PERFORMANCE DISTRIBUTION AMPLIFIER, HPDA-100
HPDA-100 OPTIONS
HPDA-100RM-A
This option provides an amplifier module with one input and five outputs in a 1U high 19” rack-mount
enclosure. The front panel contains an AC POWER LED and a signal MONITOR LED. The back panel
contains one SMA input connector, five SMA output connectors and a power entry module. The power
requirements are 110/220 VAC.
HPDA-100RM-B
This option provides three amplifier modules with one input and five outputs each in a 1U high 19” rack-mount
enclosure. The front panel contains an AC POWER LED and three signal MONITOR LEDs. The back panel
contains three SMA input connectors, fifteen SMA output connectors and a power entry module. The power
requirements are 110/220 VAC
HPDA-100RM-C
This option provides three amplifier modules with one input and five outputs each in a 1U high 19” rack-mount
enclosure. The front panel contains an AC POWER LED, a DC POWER LED and three signal MONITOR
LEDs. The back panel contains three SMA input connectors, fifteen SMA output connectors, a DC and AC
power entry connectors. This unit includes a battery backup module that allows the instrument to be powered
by a DC power source in case of loss of the main AC power. The power requirements for this model are
110/220 VAC and +24 VDC, 2A.
SpectraDynamics, Inc. ● 1849 Cherry Street Unit 2, Louisville CO, 80027 ● Phone (303) 665 1852 ● Fax (303) 604 6088
www.spectradynamics.com
All tests done at 100 MHz and +13 dBm input unless otherwise specified.
PARAMETER CONDITIONS MIN TYP MAX UNITS
Input level 1 dB compression 15 16 - dBm
Bandwidth +/- 1 dB 80 - 120 - - MHz
Gain @ 100 MHz - 0 +/- 0.5 dB
Impedance input
output
-
-
50
50
-
-
Ohms
Return loss
input (S11) 100 MHz
output (S22) 100 MHz
-
-
-22
-30
-20
-25
dB
Distortion +13 dBm - -45 -40 dBc
Isolation output to output
output to input
95
105
100
110
-
-
dB
Phase noise 10 Hz
100 Hz
1 kHz
10 kHz
-
-
-
-
-158
-165
-171
-174
-155
-162
-168
-171
dBc/Hz
SPECIFICATIONS